Amir Alexander Abdelbaki 00991b9864 Add an HTTPS reverse proxy, and auto-generate empty service tokens
TLS front door (Caddy) for this repo's own services: one hostname, a permanent
HTTP->HTTPS redirect, and the API on the same origin as the page. Home Assistant,
Grocy, Frigate and the rest keep their own ports — fronting HA brings its own
auth and websocket concerns and none of the problems below need it.

Three concrete reasons, not hygiene:

1. The admin panel's URL carries IDENTITY_TOKEN, which grants administrative
   access to the person registry AND to the device grants that decide whether a
   smart lock opens. On plain HTTP that is readable by anything on the smart-home
   VLAN — a segment deliberately full of cheap IoT hardware.
2. getUserMedia requires a secure context, so register.html's camera cannot work
   over http://192.168.x.x at all. It also failed SILENTLY: the call site used
   `navigator.mediaDevices?.getUserMedia(...).then().catch()`, and optional
   chaining short-circuits the whole chain — so neither handler ran, no "Camera
   unavailable" message appeared, and registration proceeded photo-less with no
   explanation. Verified in node. register.js now checks explicitly and says
   which of the two cases it is; HTTPS is what actually fixes it.
3. Serving the page over HTTPS while ?api= still pointed at http://...:8097 would
   have every call blocked as mixed content, so the API has to be proxied too.

tls: internal runs Caddy's own CA (no external dependency, works with no WAN at
all) with tools/export-proxy-ca.sh to fetch the root; tls: custom takes an
existing cert, which is how you'd use a real one from a DNS-01 challenge without
exposing anything. HSTS is deliberately not set — with an internal CA it would
turn a dismissible warning into a hard failure. Kiosks stay on plain HTTP for
now: a full-screen cert interstitial is not dismissible on a device with no
keyboard, so moving them is documented as a follow-up rather than done blind.

Empty service tokens now fill themselves in on the first build and land in
tokens.txt with what each is for. They are written BACK to the config, which is
the part that matters: a token is only useful because two machines agree on it,
so generating fresh randomness per build would produce a door panel that cannot
talk to the service it was built for. Blanks are filled once and never
overwritten. ha_token, mqtt_password, admin_password_hash and ssh_authorized_key
are deliberately not invented — tokens.txt lists them with the reason, so an
empty field is never a mystery.

32 new checks: token generation and stability across runs, disabled services
skipped, tokens.txt contents, config still valid after the rewrite, Caddyfile
routes and redirect, conditional pantry route, both TLS modes, and that the
derived admin URL keeps page and API on one origin. Nothing has been run against
a real Caddy — see proxy/README.md.

Co-Authored-By: Claude Opus 5 <noreply@anthropic.com>
2026-07-31 14:04:02 +02:00